SyncE

What is SyncE

SyncE (Synchronous Ethernet) is a synchronization technique based on carrying and recovering frequency information from physical layer code streams. It lets a device choose whether to use its own crystal frequency or the crystal frequency obtained from the peer port.

SyncE is commonly used together with PTP (Precision Time Protocol). The two techniques combined meet the requirements for high accuracy in both frequency and phase, and can achieve nanosecond time synchronization.

How SyncE Works

SyncE is configured per interface, and each interface takes one of two roles:

  1. Master: the interface acts as the clock source toward its peer. After SyncE is enabled on an interface, it is a master by default.

  2. Slave: the interface uses the crystal frequency obtained from the peer port instead of the device's own crystal.

When more than one interface on a device has SyncE enabled, the interface with the highest priority is selected as the clock source. Priority can be set from 0 to 255, and a smaller value means a higher priority.

For example, with two connected devices, Device A's interface is set to master and Device B's interface is set to slave. Device B then uses the crystal frequency of Device A. When PTP is also running, the SyncE mode of an interface should match its PTP mode.

Why SyncE is Beneficial

· Flexible clock source selection: Each device can use its own crystal frequency or the one obtained from the peer port, depending on its role in the network.

· Works together with PTP: SyncE and PTP are used side by side to meet both frequency and phase accuracy requirements, reaching nanosecond time synchronization.

· Clear priority control: When several interfaces have SyncE enabled, the priority value (0 to 255) decides which interface is selected as the clock source.

At Asteraix

What We Can Do at Asteraix

AsterNOS supports SyncE together with PTP, configured on each Ethernet interface through the command line.

· Per-interface SyncE configuration: SyncE is enabled on individual Ethernet interfaces with synce enable.

· Master and slave modes: Set the interface mode with synce mode {master|slave}. An interface is master by default after SyncE is enabled, and the recommended practice is to keep the SyncE mode the same as the PTP mode.

· Priority-based selection: Set the interface priority with synce priority {priority}, in the range 0 to 255. When multiple interfaces enable SyncE, the one with the highest priority is selected.

· Status visibility: show synce status displays each interface's enable state, mode, priority, and whether it is selected. show ptp interface status displays the SyncE information of an interface.